SolarEdge
P950 Power Optimizer
SolarEdge P601 Power Optimizer
SolarEdge P601 Power Optimizer, 600 W, module-level MPPT, IP68, new and unused.
SolarEdge P601 Power Optimizer – 600 W
Manufacturer: SolarEdge Technologies Ltd.
Product: SolarEdge P601 Power Optimizer
Product type: Power Optimizer
Series: P-Series
Condition: New / unused
Application: PV module-level power optimization
Product description
The SolarEdge P601 is a DC power optimizer designed for use with high-power photovoltaic modules in SolarEdge PV systems.
The P601 performs module-level Maximum Power Point Tracking (MPPT), helping optimize the energy production of individual PV modules and reducing losses caused by module mismatch, shading and different module operating conditions.
The optimizer also provides SolarEdge's SafeDC functionality, reducing the DC voltage to a safe level when the inverter is shut down or the optimizer is disconnected.
Technical specifications
Specification
SolarEdge P601
Rated DC input power
600 W
Maximum input voltage (Voc)
65 V DC
MPPT operating range
12.5–65 V DC
Maximum short-circuit current (Isc)
14.1 A
Maximum efficiency
99.5%
Maximum output current
15 A
Maximum output voltage
60 V DC
Standby/SafeDC output voltage
1 ± 0.1 V DC
Maximum system voltage
1000 V DC
Protection rating
IP68
Operating temperature
-40}C to +85}C
Relative humidity
0–100%
Dimensions
approx. 129 × 162 × 59 mm
Weight incl. cables
approx. 1.064 kg
Input connector
MC4
Output connector
MC4
Specifications are based on SolarEdge's official P-Series P601 datasheet.
Compatibility
The P601 is designed for one high-power PV module and is part of SolarEdge's P-Series optimizer range.
Important: P601 is not universally interchangeable with every SolarEdge optimizer. SolarEdge specifies compatibility and string-design requirements depending on the inverter and other optimizers used. P601 should not be mixed in the same string with P370/P401/P500 models.
Please verify compatibility with the specific SolarEdge inverter and PV module before installation.
Key features
600 W rated DC input power
Module-level MPPT
Up to 99.5% maximum efficiency
Supports high-power PV modules
IP68 enclosure
-40}C to +85}C operating temperature
SolarEdge SafeDC safety technology
MC4 connectors
Designed for SolarEdge inverter systems
Module-level monitoring when used in a compatible SolarEdge system
Condition
New / unused.
The item is offered as a genuine SolarEdge P601 Power Optimizer.
Documents
Official SolarEdge datasheet available from the manufacturer's documentation:
SolarEdge P-Series P370/P401/P404/P485/P500/P505/P601 Datasheet
SolarEdge Power Optimizers – official product information
Scope of delivery
1 × SolarEdge P601 Power Optimizer
Original cables/connectors as supplied with the unit.
Suitable for
Residential PV installations
Commercial PV installations
Replacement of existing SolarEdge P601 optimizers
SolarEdge systems using compatible high-power PV modules
New SolarEdge installations where P601 is specified by the system design
| Per pcs | 39,00 EUR |
| excl. VAT. (24 %) |
| File name | File type |
|---|---|
| se-p-series-add-on-p ... |
Customer Review
SolarEdge P601 Power Optimizer – 600 W
Manufacturer: SolarEdge Technologies Ltd.
Product: SolarEdge P601 Power Optimizer
Product type: Power Optimizer
Series: P-Series
Condition: New / unused
Application: PV module-level power optimization
Product description
The SolarEdge P601 is a DC power optimizer designed for use with high-power photovoltaic modules in SolarEdge PV systems.
The P601 performs module-level Maximum Power Point Tracking (MPPT), helping optimize the energy production of individual PV modules and reducing losses caused by module mismatch, shading and different module operating conditions.
The optimizer also provides SolarEdge's SafeDC functionality, reducing the DC voltage to a safe level when the inverter is shut down or the optimizer is disconnected.
Technical specifications
Specification
SolarEdge P601
Rated DC input power
600 W
Maximum input voltage (Voc)
65 V DC
MPPT operating range
12.5–65 V DC
Maximum short-circuit current (Isc)
14.1 A
Maximum efficiency
99.5%
Maximum output current
15 A
Maximum output voltage
60 V DC
Standby/SafeDC output voltage
1 ± 0.1 V DC
Maximum system voltage
1000 V DC
Protection rating
IP68
Operating temperature
-40}C to +85}C
Relative humidity
0–100%
Dimensions
approx. 129 × 162 × 59 mm
Weight incl. cables
approx. 1.064 kg
Input connector
MC4
Output connector
MC4
Specifications are based on SolarEdge's official P-Series P601 datasheet.
Compatibility
The P601 is designed for one high-power PV module and is part of SolarEdge's P-Series optimizer range.
Important: P601 is not universally interchangeable with every SolarEdge optimizer. SolarEdge specifies compatibility and string-design requirements depending on the inverter and other optimizers used. P601 should not be mixed in the same string with P370/P401/P500 models.
Please verify compatibility with the specific SolarEdge inverter and PV module before installation.
Key features
600 W rated DC input power
Module-level MPPT
Up to 99.5% maximum efficiency
Supports high-power PV modules
IP68 enclosure
-40}C to +85}C operating temperature
SolarEdge SafeDC safety technology
MC4 connectors
Designed for SolarEdge inverter systems
Module-level monitoring when used in a compatible SolarEdge system
Condition
New / unused.
The item is offered as a genuine SolarEdge P601 Power Optimizer.
Documents
Official SolarEdge datasheet available from the manufacturer's documentation:
SolarEdge P-Series P370/P401/P404/P485/P500/P505/P601 Datasheet
SolarEdge Power Optimizers – official product information
Scope of delivery
1 × SolarEdge P601 Power Optimizer
Original cables/connectors as supplied with the unit.
Suitable for
Residential PV installations
Commercial PV installations
Replacement of existing SolarEdge P601 optimizers
SolarEdge systems using compatible high-power PV modules
New SolarEdge installations where P601 is specified by the system design
| Company name | |
| Name of the provider | |
| Street Address | |
| Zip / City | |
| Phone | |
| Website |
| Street Address | Urda road 2/1, Jälgimäe |
| Zip / City | 76404 / Saku parish, Harju county |
| Country | Estonia |
| Per pcs | 39,00 EUR |
| excl. VAT. (24 %) |
| File name | File type |
|---|---|
| se-p-series-add-on-p ... |
Customer Review
We use cookies on our website. Some of them are essential (e.g. for the shopping cart), while others help us to improve our online offering and operate it economically. You can accept this or reject it by clicking the "Only accept essential cookies" button.
Here you will find an overview of all cookies used. You can give your consent to entire categories or have more information displayed and only select certain cookies.
Essential cookies enable basic functions and are necessary for the proper functioning of the website.
| Name | ebiztrader |
|---|---|
| Providers | No transmission to third parties |
| Purpose | Cookies to control the login process of shop customers. |
| Privacy policy | Privacy policy.htm |
| Cookie Name | ebiztrader |
| Cookie Runtime | Browser session |
| Name | cookies_consent |
| Providers | No transmission to third parties |
| Purpose | Cookie to control the information about cookies. |
| Privacy policy | Privacy policy.htm |
| Cookie Name | cookies_consent |
| Cookie Runtime | 30 Days |
| Name | cookies_consent_ad |
| Providers | No transmission to third parties |
| Purpose | Cookie to control the integration of marketing cookies. |
| Privacy policy | Privacy policy.htm |
| Cookie Name | cookies_consent_ad |
| Cookie Runtime | 30 Days |
Marketing cookies are used by third parties or publishers to display personalized advertising. They do this by tracking visitors through websites.
| I accept | off |
|---|---|
| Name | Google Analytics |
| Providers | Google LLC |
| Purpose | Google cookie for website analysis. Generates statistical data on how the visitor uses the website. |
| Privacy policy | https://policies.google.com/privacy |
| Cookie Name | _ga,_gat,_gid |
| Cookie Runtime | 2 Years |
Wartungsarbeiten
Heute von 15-23 Uhr wird unser SecondSol Marktplatz nicht erreichbar sein.
Maintenance
Today from 3pm-11pm our website will be unavailable.
Onderhoud
Vandaag van 15-23 uur zal onze website niet beschikbaar zijn.
Manetenzione
Oggi dalle 15 alle 23 il nostro sito web no sarà disponible.