Inverter
This offer is directed to tradepersons only.
Please log in as a trader, to display all productinformation.
Inverter
Aeconversion
INV315-50
The AEconversion INV315-50 micro inverter converts generated energy into grid-compliant alternating current. For this purpose, the INV315-50 is directly connected to one individual PV module. The individual conversion enables optimal utilization of sol
The AEconversion INV315-50 micro inverter converts generated energy into grid-compliant alternating current. For this purpose, the INV315-50 is directly connected to one individual PV module. The individual conversion enables optimal utilization of solar energy. The INV315-50 micro inverter is compatible with modules up to 400W with a maximum PV input voltage of 50V.
Input
· Recommended PV power: 290W - 400W
· Maximum DC voltage: 50 V
· MPPT voltage range: 24 V... 40V
· Compatible for modules with a max. current of : 14 A
Output
· Maximum AC Power: 300W
· Nominal Current: 1.2 A
· Power factor: > 0.99
Efficiency
· Peak inverter efficiency: 96 %
· European efficiency: 95 %
· MPPT-efficiency: 99.8 %
Mechanical Data
· Operating Temperature: -25 }C ... +70 }C
· Night time power consumption: 30 mW
· Max. altitude a.s.l.: 2000 m
· DC Input: Amphenol H4
· AC Output: female connector Wieland system RSTi mini
· Dimensions (WxHxD): 390mm x 100 mm x 30 mm
· Weight: 0.8 kg
· Cooling: natural convection
· Enclosure material: aluminum
· Protection Degree: IP65 ( iP67 ) & NEMA4
50 Hz-Version
· Nominal AC voltage: 230 V
· Nominal AC voltage range: 184V ... 264V
· Frequency: 50.0 Hz
· Frequency range: 47.5 Hz ... 51.5 Hz
60 Hz-Version
· Nominal AC voltage: 208 V or 240 V
· Nominal AC voltage range: 184V ... 264V
· Frequency: 60.0 Hz
· Frequency range: 59.5 Hz ... 60.3 Hz
Safety and standards
· Productsafety:
IEC 62109-1
IEC62109-2
UL1741
IEEE 1547
CSA C22.2
· EMC: IEC 61000-6-3
IEC 61000-6-4
IEC 61000-6-1
IEC 61000-6-2
Features
· Communication Version: smart RF communication
· Safety class: Class I
· Topology: Transformer/galvanically isolated
· integrated safety features
Please login with your user name and your password.
Please login with your user name and your password.
This offer is directed to tradepersons only
| File name | File type |
|---|---|
| AEconversion Checkli ... | |
| AEconversion INV315- ... | |
| AEconversion INV315- ... | |
| AEconversion Micro-W ... | |
| AEconversion INV315- ... | |
| AEconversion INV315- ... | |
| AEconversion INV315- ... | |
| AEconversion INV315- ... |
Customer Review
These could also be interesting:
Similar Performance
The AEconversion INV315-50 micro inverter converts generated energy into grid-compliant alternating current. For this purpose, the INV315-50 is directly connected to one individual PV module. The individual conversion enables optimal utilization of solar energy. The INV315-50 micro inverter is compatible with modules up to 400W with a maximum PV input voltage of 50V.
Input
· Recommended PV power: 290W - 400W
· Maximum DC voltage: 50 V
· MPPT voltage range: 24 V... 40V
· Compatible for modules with a max. current of : 14 A
Output
· Maximum AC Power: 300W
· Nominal Current: 1.2 A
· Power factor: > 0.99
Efficiency
· Peak inverter efficiency: 96 %
· European efficiency: 95 %
· MPPT-efficiency: 99.8 %
Mechanical Data
· Operating Temperature: -25 }C ... +70 }C
· Night time power consumption: 30 mW
· Max. altitude a.s.l.: 2000 m
· DC Input: Amphenol H4
· AC Output: female connector Wieland system RSTi mini
· Dimensions (WxHxD): 390mm x 100 mm x 30 mm
· Weight: 0.8 kg
· Cooling: natural convection
· Enclosure material: aluminum
· Protection Degree: IP65 ( iP67 ) & NEMA4
50 Hz-Version
· Nominal AC voltage: 230 V
· Nominal AC voltage range: 184V ... 264V
· Frequency: 50.0 Hz
· Frequency range: 47.5 Hz ... 51.5 Hz
60 Hz-Version
· Nominal AC voltage: 208 V or 240 V
· Nominal AC voltage range: 184V ... 264V
· Frequency: 60.0 Hz
· Frequency range: 59.5 Hz ... 60.3 Hz
Safety and standards
· Productsafety:
IEC 62109-1
IEC62109-2
UL1741
IEEE 1547
CSA C22.2
· EMC: IEC 61000-6-3
IEC 61000-6-4
IEC 61000-6-1
IEC 61000-6-2
Features
· Communication Version: smart RF communication
· Safety class: Class I
· Topology: Transformer/galvanically isolated
· integrated safety features
| Company name | |
| Name of the provider | |
| Street Address | |
| Zip / City | |
| Phone | |
| Website |
| Street Address | Frauenstraße 32 |
| Zip / City | 82216 / Maisach |
| Country | Germany |
| File name | File type |
|---|---|
| AEconversion Checkli ... | |
| AEconversion INV315- ... | |
| AEconversion INV315- ... | |
| AEconversion Micro-W ... | |
| AEconversion INV315- ... | |
| AEconversion INV315- ... | |
| AEconversion INV315- ... | |
| AEconversion INV315- ... |
Customer Review

(0 customer ratings)