Accessori

49,00 EUR / pz.
escl. IVA. (20 %)
Numero articolo
48157 (402 views)
Disponibilità 24 pz / da a partire da ora
Quantità minima d'ordine
Metodo di spedizione A richiesta
Informazioni sul venditore
Fornitore di affari
Registrato da allora 19.02.2026
Categoria Accessori / Sicurezza / Sicurezza di moduli e inverter
Descrizione

Model:

product brand name: SENTRON

product designation: RCBO

design of the product: Instantaneous

 

General technical data:

number of poles: 2

number of poles with protection: 1

design of pole: 1P+N

tripping characteristic class: C

mechanical service life (operating cycles) typical: 10 000

overvoltage category: 3

degree of pollution: 2

 

Voltage:

type of voltage of the operating voltage: AC

insulation voltage (Ui) rated value: 264 V

surge voltage resistance rated value: 4 000 V

surge current resistance at (8/20) µs: 1 kA

tripping fault current rated value: 30 mA

● operational current

— at 30 °C rated value

10 A

— at 40 °C rated value

9.5 A

— at 45 °C rated value

9.3 A

— at 50 °C rated value

9 A

— at 55 °C rated value

8.7 A

— at 60 °C rated value

8.5 A

— at 65 °C rated value

8.2 A

— at 70 °C rated value

8 A

● operational current at AC rated value: 10 A

residual current type: A

 

Supply Voltage: 

supply voltage

● at AC rated value: 230/240 V

● for testing equipment minimum: 195 V

operating frequency: 50 Hz

supply voltage frequency rated value: 50 Hz

 

Protection class:

protection class IP: IP20, if the distribution board is installed, with connected conductors

 

Breaking Capacity:

switching capacity current

● according to EN 60898 rated value: 10 kA

● according to IEC 60947-2 rated value: 20 kA

short-circuit current breaking capacity (Icn) according to EN 61009-1 rated value: 10 kA

rated residual switching capacity (IΔm) according to IEC 61009-1: 10 kA

energy limitation class: 3

 

Connections:

connectable conductor cross-section solid

● minimum: 0.75 mm²

● maximum: 35 mm²

connectable conductor cross-section stranded

● minimum: 0.75 mm²

● maximum: 35 mm²

connectable conductor cross-section finely stranded with core end processing

● minimum: 0.75 mm²

● maximum: 25 mm²

tightening torque with screw-type terminals

● minimum: 2.5 N·m

● maximum: 3 N·m

position of power supply cord: Either top or bottom

 

Mechanical Design

height: 90 mm

width: 36 mm

depth: 77 mm

installation depth: 70 mm

number of modular width units: 2

mounting position: any

Net Weight: 272 g

 

 

 


Informationi generali
Produttore Siemens
Tipo FI Schutzschalter
Categoria Sicurezza di moduli e inverter
Tipo Rimanenze
Condizioni Nuovo
Età sconosciuto
Ricambio speciale. No
Informazioni di contatto del venditore

Si prega di eseguire il login con il tuo indirizzo nome utente e la password.

VAI AL LOGIN

Posizione del prodotto

Si prega di eseguire il login con il tuo indirizzo nome utente e la password.

VAI AL LOGIN

Listino prezzi
Per pezzo 49,00 EUR
escl. IVA. (20 %)
pagamento:
Fattura,
Modalità di pagamento:
Bonifico,
Documenti da scaricare
Nome file Tipo di file
5SU13547KK10_datashe ... pdf

ti potrebbe anche interessare:

J.Pröpster

P-VMS 600 Überspannu ...

35,00 EUR/pz.


Huawei

Safety Box Smart PSB2000L

95,00 EUR/pz.


Fronius

Grounding Kit 100K

41,00 EUR/pz.


ABB

OTP16BA4M DC-Schalter ...

28,00 EUR/pz.


Descrizione

Model:

product brand name: SENTRON

product designation: RCBO

design of the product: Instantaneous

 

General technical data:

number of poles: 2

number of poles with protection: 1

design of pole: 1P+N

tripping characteristic class: C

mechanical service life (operating cycles) typical: 10 000

overvoltage category: 3

degree of pollution: 2

 

Voltage:

type of voltage of the operating voltage: AC

insulation voltage (Ui) rated value: 264 V

surge voltage resistance rated value: 4 000 V

surge current resistance at (8/20) µs: 1 kA

tripping fault current rated value: 30 mA

● operational current

— at 30 °C rated value

10 A

— at 40 °C rated value

9.5 A

— at 45 °C rated value

9.3 A

— at 50 °C rated value

9 A

— at 55 °C rated value

8.7 A

— at 60 °C rated value

8.5 A

— at 65 °C rated value

8.2 A

— at 70 °C rated value

8 A

● operational current at AC rated value: 10 A

residual current type: A

 

Supply Voltage: 

supply voltage

● at AC rated value: 230/240 V

● for testing equipment minimum: 195 V

operating frequency: 50 Hz

supply voltage frequency rated value: 50 Hz

 

Protection class:

protection class IP: IP20, if the distribution board is installed, with connected conductors

 

Breaking Capacity:

switching capacity current

● according to EN 60898 rated value: 10 kA

● according to IEC 60947-2 rated value: 20 kA

short-circuit current breaking capacity (Icn) according to EN 61009-1 rated value: 10 kA

rated residual switching capacity (IΔm) according to IEC 61009-1: 10 kA

energy limitation class: 3

 

Connections:

connectable conductor cross-section solid

● minimum: 0.75 mm²

● maximum: 35 mm²

connectable conductor cross-section stranded

● minimum: 0.75 mm²

● maximum: 35 mm²

connectable conductor cross-section finely stranded with core end processing

● minimum: 0.75 mm²

● maximum: 25 mm²

tightening torque with screw-type terminals

● minimum: 2.5 N·m

● maximum: 3 N·m

position of power supply cord: Either top or bottom

 

Mechanical Design

height: 90 mm

width: 36 mm

depth: 77 mm

installation depth: 70 mm

number of modular width units: 2

mounting position: any

Net Weight: 272 g

 

 

 


Informationi generali
Produttore Siemens
Tipo FI Schutzschalter
Categoria Sicurezza di moduli e inverter
Tipo Rimanenze
Condizioni Nuovo
Età sconosciuto
Ricambio speciale. No

Informazioni di contatto del venditore
z
Nome dell'azienda
Nome del provider
Indirizzo
CAP / Città
numero di telefono
Email
Sito web

Posizione del prodotto
Indirizzo Galgenau 51
CAP / Città 4240 / Freistadt
Paese Austria

Listino prezzi
Per pezzo 49,00 EUR
escl. IVA. (20 %)

Documenti da scaricare
Nome file Tipo di file
5SU13547KK10_datashe ... pdf